format - EDI, 852 Product Transfer: N1 loop out of order? -
i have build edi report i'm working on. i'm using edi notepad validate output. while edi readable edi notepad, keep getting errors have few n1
loops out of order. gives?
i've been reading through spec afternoon trying figure out, , see no mention of n1
order anywhere. doing wrong?
here's edi in question:
isa*00* *00* *12*abccom *01*999999999 *110127*1719*u*00400*000005438*0*p*>~ gs*pd*4405197800*999999999*20110127*1719*1421*x*004010vics~ st*852*000008315~ xq*g*20130807*20130807~ n1*st**11*ad6448446~ lin**ua*53233*pi*76189053560~ za*qa*0*ea~ za*qs*0*ea~ lin**ua*53234*pi*76189053430~ za*qa*0*ea~ za*qs*0*ea~ n1*st**11*bd9628542~ lin**ua*53234*pi*76189053430~ za*qa*30*ea~ za*qs*0*ea~ lin**ua*53233*pi*76189053560~ za*qa*0*ea~ za*qs*60*ea~ n1*st**11*fd0286244~ lin**ua*53233*pi*76189053560~ za*qa*180*ea~ za*qs*930*ea~ lin**ua*53234*pi*76189053430~ za*qa*390*ea~ za*qs*585*ea~ n1*st**11*bd9076008~ lin**ua*53234*pi*76189053430~ za*qa*0*ea~ za*qs*0*ea~ lin**ua*53233*pi*76189053560~ za*qa*0*ea~ za*qs*0*ea~ n1*st**11*fd0417825~ lin**ua*53234*pi*76189053430~ za*qa*30*ea~ za*qs*30*ea~ lin**ua*53233*pi*76189053560~ za*qa*0*ea~ za*qs*0*ea~ n1*st**11*bw0222264~ lin**ua*53234*pi*76189053430~ za*qa*90*ea~ za*qs*90*ea~ lin**ua*53233*pi*76189053560~ za*qa*240*ea~ za*qs*60*ea~ ctt*12~ se*46*000008315~ ge*1*1421~ iea*1*000005438~
according ansi standard, have n1 child of lin, not part of standard. sdq segment implemented address / quantity in detail loop.
if remove n1 segments (all 1 xq), you'll notice edi notepad won't display error. if spec has detail n1, using own "version" of standard. not uncommon, means.